Photometric sphere to measure light of the lamp.
Measurement are done with stabilized voltage supply and sophisticated meter.
We have Standard Bulbs (Master Bulb) duly calibrated from ARAI(Automotive Research Association of India) with which our system is calibrated
Test Performance results are monitored & parameters are controlled by computer As per IEC 60810.
Vibration M/c for – Rasonance, Random, shock-test, sign on random etc.
To check the bonding between the cap and glass shell.
Servo Controlled Voltage Stabilizer are used for controlling the voltage as per standard specification of ±0.5% Regulation.
Cyclic Test is Conducted for 20000 Cycle.15 Seconds “ON” & 15 Seconds “OFF”.